3 Attachment(s) Can't let the unit run longer then a minut other wise my compressor freezes, to much gass on it and bad evap lol Made a new simple design going to call it evap 53 :D |
make sure u got good hitting space for the gas and u will have a nice evap. thoughe that disign would work nice, with a 3mm thick base. |
Quote:
|
Quote:
|
Quote:
How is your cascade? *edit* could you post what your idea would be as a good evap? tekening ofzo lol ^^ |
cascade work and is standing right behind me, for evap i would go with maze disign. see XS maybe they got some things u can check. how long is the cap tube ? |
Quote:
|
At the moment i'm having a vaccuum pump connected to my system, within an hour or so i can tell how much difference my new test with other evap design will give me :D I hope i can reach at least -1986°c ^^ |
Quote:
|
New evap = better results like said :D This weekend when i have the time i'm going to finetune the system , it reaches easy -45°c and still dropping but i need to insulate the suction line and lett of some gas, (compressor freezing) For now i'm happy :D My final results will come when i have the time to charge the system with either R410a or R402A, i can expect big improvements with those gasses . I took the R417A cause all other gasses would require new type of oil :) To make a small compar. R417a = - 41,8 *C, boiling point R507 = - 47.2 *C boiling point in 0 bars. R410a = -48.5 *C boiling point R402a = - 49.2 *C boiling point |