Cascade + little brother? Hey MAD men :D Early 2010 i'll be ordering cooling parts from Poland, I've asked Piotres to "makeme an offer i cannote refuse" :p this is part 1 I wanted a massive cascade that could handle -100° at around 250W load orso. Then i thaught, why not have a little unit build for vga aswell and this is his idea ... I like it but i have contradictory thaughts about it and would like your input :) Afterall, i won't be the only one using it i should hope ;) Mainly, what do you think about it and most importantly, about it's usefulness. Specs: Quote:
Also a dualchip card becomes difficult, i think the chips would be to close to eachother. But on the other hand, it can be used as 2 separate single stages, so 2 benchers with 1 vga each for instance, is also possible :) That's for the "little brother". That poor man is so busy the cascade offer is due for the near future :D |
And you are going to build it yourself? |
What do you think? Quote:
|
I wish :-/ No mate, "Piotres" would be doing the building, it's his plans aswell ;) |
Quote:
Early 2010 i'll be ordering cooling parts from Poland, ordering parts as in seperate pieces from poland. Anyhow doesn't matter, can't wait to see it in action :) |
Ok i phrased it badly :D i meant it as in the units themselves are the cooling parts. But i would like to know if you would have one like this build, or if you rather would leave it at a single evap unit ... |
Quote:
not that he will be making a cascade ;p |
Quote:
But you have to descide that on your own. What fits your needs. |
Well i can imagine using the dual evap system often enough, but i think i mainly would be running a single evap rather then both. That's where my doubts are ... It sure can come in handy, but is it worth it? Pricewise: dual evap = roughly 150% of the single evap unit. intresting enough to think hard :p |
I would go for a strong single evap cascade :D |
Hmm, vga's won't really profit from more cold, or am i wrong? Strong cascade is also in the plans but that offer is being written in the next few days ;) |
They have processors, just like mainboards have. |
so in the end: how would you have this build done? |
if u go for dual evap and single compressor take 12000btu rotary to be good. for 2 stage cascade arround 10000btu rotary's will give u -95°C load @ 250watt with normal room temps. gij leest mijn gedachten :D. |
Dual evap would and should be with 2 compressors, to run 1 OR both, when needed :D The cascade ... i'm anxious to receive his offer ... it should be -1xx° @ those loads ;) :naughty: |
u have been thinking u can only take a maximum off 2000watt out off ure room's socket :p ? |
By the time it arrives i'll have a warehouse orso available ;) If that thing enters my house i'm a dead man, mark the words of my GF :D |